Effect of different implant positions for two implant-retained mandibular overdenture: a retrospective 5-years radiographic evaluation of the circumferential peri-implant bone loss and posterior ridge resorptive changes
Résumé
BACKGROUND: Studies did not recommend which position for implant overdenture poses the lowest biomechanical risk and the least chance of peri-implant bone loss and ridge resorption for those who might need a mandibular two-implant overdenture. The study objectives were to investigate the impact of implant position, in lateral incisors or canine positions, on peri-implant bone loss and posterior ridge resorption. METHODS: Fifty patients with mandibular two-implants were recalled and divided according to the implant position into two groups (group L: implants in lateral incisor positions and group C: implants in canine positions). The circumferential peri-implant bone level and posterior ridge resorption were assessed at implant insertion (T0), one year later (T1), and five years later (T5) using the follow-up CBCT. Data were analyzed using the Statistical Package of Social Science (SPSS) program. A Mann-Whitney test was used to compare two different groups. Paired groups were compared using the Wilcoxon signed-rank test. The threshold of significance is fixed at a 5% level (p-value). RESULTS: Significant differences in the vertical bone loss between groups appeared at (T5 - T1) (Mann Whitney test, (P = 0.01)) and at (T5 - T0) (Mann Whitney test, (P = 0.005)), and a significant difference in horizontal bone loss between groups was found at (T1 - T0) (Mann Whitney test, (P = 0.041)) and (T5 - T1) (Mann Whitney test, (P = 0.041)). Also, there were significant differences over the evaluation period between groups at certain points along the ridge at M1 (Mann Whitney test, (P = 0.021)), M3 (Mann Whitney test, (P = 0.008)), and M4 (Mann Whitney test, (P = 0.015)). CONCLUSIONS: According to the findings of this clinical study, the placement of implants in the lateral incisor position for two implant-retained overdentures is a viable choice. In comparison to the canine position, the lateral incisor position demonstrated superior peri-implant responses, which could potentially enhance the longevity of the implants. Furthermore, the placement of implants in the lateral incisor position can promote a more even distribution of stress and help mitigate posterior ridge resorption. Conversely, implants in the canine position may cause a seesaw effect and result in greater posterior ridge resorption. CLINICAL TRIAL REGISTRY NUMBER: (NCT06055842) (13/03/2024).
Citer ce document
Accès au document
Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter
Voir l'article sur le site de la revueStatistiques
Consultations : 1
Téléchargements : 0