Accès ouvert

Review of top notch electrode arrays for geoelectrical resistivity surveys

Article scientifique 2020 Anglais

Résumé

The different arrangements of electrodes used in geoelectrical resistivity surveys and measurements are referred to as electrode arrays. In this review, we have revisited most of the widely used electrode arrays as well as the uncommon ones, which are nonetheless, useful in certain situations. This review has provided detailed information about eleven (11) of the top notch electrode arrays employable in our regular resistivity surveys, making it clear that in practice, the arrays that are most commonly used for 2-D imaging surveys are the Wenner, Dipole-Dipole, Wenner-Schlumberger, Pole-Pole and the Pole-Dipole arrays. They have their strengths and weaknesses. They are typically described by their signal-to-noise ratio. Their depth of investigation, ability for lateral location of the target and their mapping abilities of horizontal layers or steeply dipping structures among other factors determine which array to adopt.

Citer ce document

Ohaegbuchu, H., Anyadiegwu, F., Odoh, P., Orji, F. (2020). Review of top notch electrode arrays for geoelectrical resistivity surveys. https://doi.org/10.46481/jnsps.2019.34

Accès au document

Voir sur le dépôt source

Ce document est hébergé sur son dépôt institutionnel d'origine.

Statistiques

Consultations : 1

Téléchargements : 0