Centrally adapted optimal control of multiple electric water heaters

Article scientifique 2021 Anglais

Résumé

Breakthroughs in smart grid technology make it possible to deliver electricity in controlled and intelligent ways to improve energy efficiency between the user and the utility. Demand-side management strategies can reduce overall energy usage and shift consumption to reduce peak loads. Electric water heaters account for 40% of residential energy consumption. Since they are thermal storage devices, advanced control strategies can improve their efficiency. But existing methods disregard the connection between the user and the grid. We propose a centrally adapted control model that allows for coordinated scheduling to adapt the optimal control schedule of each EWH, spreading the load into off-peak periods to ensure that the grid's generation capacity is not exceeded. We consider two strategies for the delivery of hot water, temperature matching, and energy matching with \textit{Legionella} sterilisation, and compare them to a baseline strategy where the thermostat is always switched on. Simulation results for a grid of 77 EWHs showed that an unconstrained peak load of 1.05 kW/EWH can be reduced as low as 0.4 kW/EWH and achieve a median energy saving per EWH of 0.38 kWh/day for the temperature matching strategy and 0.64 kWh/day for the energy matching strategy, without reducing the user's comfort.

Citer ce document

Ritchie, M., Engelbrecht, J., Booysen, M. (2021). Centrally adapted optimal control of multiple electric water heaters. https://doi.org/10.31224/osf.io/a52dw

Accès au document

Voir sur le dépôt source

Ce document est hébergé sur son dépôt institutionnel d'origine.

Statistiques

Consultations : 1

Téléchargements : 0