Accès ouvert

Measurement properties and responsiveness of the EQ-5D-Y-5L compared to the EQ-5D-Y-3L in children and adolescents receiving acute orthopaedic care

Article scientifique 2022 Anglais

Résumé

OBJECTIVE: The aim of this study is a head-to-head comparison of the instrument performance and responsiveness of the EQ-5D-Y-3L and the expanded English version of the EQ-5D-Y-5L in children/adolescents receiving acute orthopaedic management in South Africa. METHODS: Children/adolescents aged 8-15 years completed the EQ-5D-Y-5L, EQ-5D-Y-3L, self-rated health (SRH) question and PedsQL at baseline. The EQ-5D-Y-5L, EQ-5D-Y-3L and SRH question were repeated after 24 and 48 h. Performance of the EQ-5D-Y-5L and EQ-5D-Y-3L was determined by comparing feasibility (missing responses), redistribution of dimensions responses, discriminatory power, concurrent validity, and responsiveness. RESULTS: Eighty-three children/adolescents completed baseline measures and seventy-one at all three time-points. Reporting of 11111 decreased by 20% from the EQ-5D-Y-3L to the EQ-5D-Y-5L. Informativity of dimensions improved on average by 0.267 on the EQ-5D-Y-5L with similar evenness. There was a range of 11-27% inconsistent responses when moving from the EQ-5D-Y-3L to the EQ-5D-Y-5L. There was a low to moderate and significant association on the EQ-5D-Y-3L and EQ-5D-Y-5L to similar items on the PedsQL and SRH scores. Percentage change over time was greater for the EQ-5D-Y-5L (range 0-182%) than EQ-5D-Y-3L (range 0-100%) with the largest reduction for both measures between 0 and 48 h. For those who respondents who showed an improved SRH the EQ-5D-Y-5L and EQ-5D-Y-3L showed significant paired differences. CONCLUSION: The English version of the EQ-5D-Y-5L appears to be a valid and responsive extension of the EQ-5D-Y-3L for children receiving acute orthopaedic management. The expanded levels notably reduce the ceiling effect and has greater discriminatory power. Concurrent validity of the EQ-5D-Y-3L and EQ-5D-Y-5L was low to moderate with similar PedsQL items and SRH. The EQ-5D-Y-5L generally showed greater change than the EQ-5D-Y-3L across all dimensions with the greatest change observed for 0-48 h. Responsiveness was comparable across the EQ-5D-Y-3L and EQ-5D-Y-5L for those with improved SRH. Greater sensitivity to change may be observed on comparison of utility scores, once preference-based value sets are available for the EQ-5D-Y-5L.

Citer ce document

Verstraete, J., Marthinus, Z., Dix-Peek, S., Scott, D. (2022). Measurement properties and responsiveness of the EQ-5D-Y-5L compared to the EQ-5D-Y-3L in children and adolescents receiving acute orthopaedic care. https://doi.org/10.1186/s12955-022-01938-6

Accès au document

Voir sur le dépôt source

Ce document est hébergé sur son dépôt institutionnel d'origine.

Statistiques

Consultations : 1

Téléchargements : 0