Accès ouvert

Observance des Mesures de Radioprotection en Milieu Hospitalier Public à Yaoundé en 2016

Article scientifique 2019 Français

Résumé

RESUMEIntroduction. La radioprotection est un ensemble de regles et procedures edictees par des reglementations internationales. Au Cameroun, l’Agence Nationale de Radioprotection (ANRP) a ete creee pour assurer la surete et la securite radiologique et nucleaire. L’objectif de notre travail etait d’etudier l’observance des mesures de radioprotection en milieu hospitalier a Yaounde. Materiels et Methodes. Une enquete transversale descriptive d’une duree de 5 mois (du 10 janvier au 25 Mai 2016) a ete conduite chez lepersonnel medical, paramedical et administratif regulierement affectes dans les services de radiologie – imagerie de 6 structures hospitalieres a Yaounde. Les donnees ont ete recueillies a l’aide dedeux fiches d’enquete. La premiere etait destinee aux travailleurs et la deuxieme renseignait sur les mesures de radioprotection et les donnees relatives au controle effectue par l’organisme habilite. Resultats. La population d’etude etait a predominance de sexe masculin (56,5%), avec un sex-ratio de 1,3. La moyenne d’âge des agents etait de 38 ans et des extremes de 24 ans et 65 ans. Les categories professionnelles les plus representees etaient les techniciens en radiologie (48%) suivis des medecins radiologues (36,9%). Les principales mesures de radioprotection existantes et connus par les travailleurs etaient l’ecran plombe, le tablier plombe, la formation sur les risques lies aux rayonnements ionisants et l’existence d’une PCR dans respectivement 100%, 82,6 %, 71,7 % et 60,8 %. Au plan technique individuel, la majorite des travailleurs affirmaient avoir un tablier plombe en zone d’exposition a leur disposition, cependant aucune structure ne disposait de lunette de protection ni de protege-gonade. Selon l’ANRP, 50% des etablissements hospitaliers concernes avaient une autorisation d’ouverture et d’utilisation des generateurs de rayons X. Par ailleurs, aucun site ne disposait de dosimetre d’ambiance, ni de signalisation de zone controlee et surveillee et n’avait mis au point un programme de formation continue en radioprotection au sein de son etablissement. Toutefois tous les centres de l’etude (100%) disposaient d’une personne competente en radioprotection (PCR). Conclusion. L’application des sanctions prevues par la loi sur la radioprotection au Cameroun en cas du non-respect des mesures de radioprotections pourra en ameliorer l’observance.ABSTRACTIntroduction. Radiation protection is a set of rules and procedures enacted by international regulations. In Cameroon, the National Radiation Protection Agency (NRPA) was created to ensure radiological and nuclear safety and security. The objective of our work was to study the observance of radiological protection measures in hospitals in Yaounde. Materials and Methods. A descriptive cross-sectional survey lasting 5 months (from January 10th to May 25th, 2016) was carried out on medical, paramedical and administrative staff regularly assigned to the radiology - imaging departments of 6 hospitals in Yaounde. The data were collected using two survey cards. The first was for the workers and the second sheet provided information on the existing radiation protection measures and the data on the control carried out by the authorized organization. Results. The study population was predominantly male (56.5%), with a sex ratio of 1.3. The average age of the agents was 38 years and extremes of 24 years and 65 years. The most represented professional categories were radiology technicians (48%) followed by radiologists (36.9%). The main radiation protection measures existing and known by the workers were the leaded screen, the leaded apron, the training on the risks related to the ionizing radiations and the existence of a CPR in respectively 100%, 82,6% , 71.7% and 60.8%. At the individual technical level, the majority of the workers claimed to have a leaded apron in the exposure zone at their disposal, however no structure had protective glasses or gonad guards. According to the NRPA, 50% of the hospitals concerned had an authorization to open and use X-ray generators. In addition, no site had a room dosimeter or a controlled and monitored zone signaling system and had developed a continuing education program in radiation protection at his institution. However, all centers in the study (100%) had a CPR. Conclusion. The application of the sanctions provided by the law on radiation protection in Cameroon in case of non-compliance with radiation protection measures may improve compliance.

Citer ce document

Guiegui, C., Owona, J., Aka, I., N’gassam, L., Affoue, L., Kra, A., Ya, M., Sangah, B. (2019). Observance des Mesures de Radioprotection en Milieu Hospitalier Public à Yaoundé en 2016.

Accès au document

Voir sur le dépôt source

Ce document est hébergé sur son dépôt institutionnel d'origine.

Statistiques

Consultations : 1

Téléchargements : 0