Human Breast Milk Assessed by the Deuterium Dose Mother Technique with Less Than 30 g Deuterium Using the Agilent 4500S for Fourier Transform Infrared Spectroscopy: A Pilot Study in the Democratic Republic of Congo

Article scientifique 2020 Anglais

Résumé

Abstract Background: Good breastfeeding practice is essential in preventing malnutrition in children. The deuterium method is the best technique for assessing human breast milk output. We investigated whether deuterium doses < 30 g can be used to assess human breast milk using saliva and the new Agilent 4500S for Fourier transform infrared spectroscopy (FTIR). Methods: In a cross-sectional study, the breastmilk output of lactating mothers was evaluated using four different doses of deuterium in the Miti-Murhesa Health Zone (Democratic Republic of Congo). Lactating mothers of infants aged 3-23 months were recruited and assigned to a dosage group. Weight, height, and mid-upper arm circumference were measured and the body mass index calculated as weight/height2. Body composition (fat mass, free fat mass, total body water, and breastmilk output) was assessed using standard deuterium dilution methods. One-way ANOVA was used to compare the means in different groups and the chi² test to compare proportions. Results: Seventy-five lactating mothers were included in the study: 19 received 6 g, 20 received 10 g, 18 received 15 g, and 18 received 20 g deuterium. The mean ± standard deviation infant age was 10.6 ± 5.2, 11.1 ± 4.4, 10.9 ± 4.4, and 11.0 ± 3.9 months, respectively (p=0.076). We found no difference in the age and anthropometric parameters of the lactating mothers in the different groups. The mean ± standard deviation breast milk output rate was 796.6 ± 292.4, 260.8± 23.2, 749.8 ± 244.2, and 733.6 ± 207.1 g/d in the 6 g, 10 g, 15 g, and 20 g groups, respectively (p=0.883). Conclusions: The different doses of deuterium administered to lactating mothers resulted in similar breast milk output values. Thus, it is possible to evaluate human breast milk with deuterium doses <30 g when using the Agilent 4500S.

Citer ce document

Murhima’alika, C., Maheshe, G., Mapendo, D., Kapapa, A., Munthali, G., Owino, V., Wilmet, M., Donnen, P., Bisimwa, G. (2020). Human Breast Milk Assessed by the Deuterium Dose Mother Technique with Less Than 30 g Deuterium Using the Agilent 4500S for Fourier Transform Infrared Spectroscopy: A Pilot Study in the Democratic Republic of Congo. https://doi.org/10.21203/rs.3.rs-111948/v1

Accès au document

Voir sur le dépôt source

Ce document est hébergé sur son dépôt institutionnel d'origine.

Statistiques

Consultations : 1

Téléchargements : 0